EN     |    FA

Signs Guide

Signs Guide 1

Radiation angle

The angle of light exiting the lamp

Signs Guide 3

Protection level

Resistance to water, dirt and dust ingress

Signs Guide 5

Sensor-controlled lighting

Turns on and off without the need for a key

Signs Guide 7

Emergency lighting

Turning on during a power outage

Signs Guide 9

Cutting width

Width of cutout on ceiling and wall for linear lights

Signs Guide 11

Cutting diameter

Cutting diameter size for round and square lights

Signs Guide 13

Interior

Using lights indoors or in enclosed spaces

Signs Guide 15

External space

Using lights in outdoor environments or open spaces

Signs Guide 17

Driver +

Change the default driver to a custom one

Signs Guide 19

LED turn-on voltage

The input voltage is DC voltage (direct voltage).

Signs Guide 21

Surface Light

Lights that are mounted directly on walls or ceilings

Signs Guide 23

Built-in light

Lights installed in a false ceiling have only the front part that emits light visible.

Signs Guide 25

Pendant lamp

Lights that hang from the ceiling and spread light down or around in a focused or wide way

Signs Guide 27

LED input voltage

The amount of voltage it requires to turn on and operate.

Signs Guide 29

Lifespan

High durability, long service life, stable performance

Signs Guide 31

Radiation angle

The international symbol representing the recycling process, which has the ability to be recycled and transformed into a new product.

Signs Guide 33

International standard

International standard for quality management system

Signs Guide 35

Electrical safety

Grounding system

Signs Guide 37

Iranian Standard (ISIRI)

Product production in accordance with the requirements and regulations set by the Iranian Institute of Standards and Industrial Research

Signs Guide 39

European standard

Mark of conformity of the product with European Union standards

Exclusive features of Alton drivers

flicker rang
transient voltage immunity
efficiency at full load
total harmonic distortion(THD)
power factor at full load
.
No flicher
1.5KV
More than 92%
THD > 130
PF < 0.6
Signs Guide 41
No flicher
3KV
More than 92%
THD < 45%
PF < 0.9
Signs Guide 43
40% > flicher
3KV
More than 92%
THD < 18%
PF > 0.95
Signs Guide 45
No flicher
3KV
More than 92%
THD < 18%
PF > 0.95
Signs Guide 47
20% > flicher
3KV
More than 92%
THD < 8%
PF > 0.98
Signs Guide 49
No flicher
3KV
More than 92%
THD < 8%
PF > 0.98
Signs Guide 51

Common Features of Alton Ray Drivers

Constant current driver design
Input voltage range 110VAC_265VAC
Operating frequency 47Hz_50Hz
Protection against short circuit, overload, and overvoltage according to IEC62384 standard (Iranian National Standard 16075, Clause 12)
Protection against mains power surges (withstands 300VA voltage for up to 72 hours)
Stabilizing light level and power consumption during fluctuations in mains voltage 110VAC ~ 300VAC
100% tested at full load
Operating capability within a temperature range of -20°C to +50°C
Get a quote